1. System Arming mode
Active: the transmitter must be used to arm the system1.
Passive Arm w/o lock: after exiting the vehicle the system will automatically arm. The doors will not 2.
lock
Passive Arm w/lock: after exiting the vehicle the system will automatically arm and lock the doors3.
Auto re-arm w/o lock: if the vehicle is not entered after receiving a disarm command, the system will 4.
automatically re-arm. The doors will not lock
Auto re-arm w/lock: if the vehicle is not entered after receiving a disarm command, the system will 5.
automatically re-arm and lock the doors
2. Panic Mode
On: the Panic output can be activated at any time1.
Ign Off Only : the Panic output can be activated only when the ignition is off2.
Off: the Panic output is defeated3.
3. Confirmation Chirps
On w/Warn Chirps On: arm, disarm, and sensor warn-away chirps are active1.
On w/Warn Chirps Off: arm and disarm chirps are active, warn-away chirps are defeated2.
Off w/Warn Chirps On: arm and disarm chirps are defeated, warn-away chirps are active3.
Off w/Warn Chirps Off: arm, disarm, and sensor warn-away chirps are defeated4.
4. Siren Duration
30sec: the siren output for full trigger activations and Panic mode is 30 seconds1.
60sec: the siren output for full trigger activations and Panic mode is 60 seconds2.
5. Ign-controlled Locks
No Ign-locking: the door lock/unlock outputs will not activate when ignition is turned on/off1.
Lock & Unlock: the door lock & unlock output will activate when ignition is turned on & off2.
Lock Only: the door lock output will activate when ignition is turned on3.
Unlock Only: the door unlock output will activate when ignition is turned off4.
6. Door Lock Pulses
Single: the door lock & unlock outputs will pulse once1.
Double Unlock only: the unlock output only will pulse twice2.
Double Lock Only: the lock output only will pulse twice3.
Double Lock & Unlock: the lock & unlock outputs will pulse twice4.
7. Door Lock Output Duration
0.8sec.: the door lock output pulses will be 800mS in duration1.
3.5sec.: the door lock pulses will be 3.5 seconds in duration2.
0.4 sec.: the door lock pulses will be 400mS in duration3.
8. Ignition Controlled 2nd Unlock
After first unlock: for Ign-controlled unlocking, the 2nd unlock will activate 800mS after the first (driver 1.
door) unlock
With first unlock: for Ign-controlled unlocking, the 2nd unlock will activate at the same time as the first 2.
(driver door) unlock
9. Comfort Closure
No comfort Closure: Comfort Closure is defeated when arming1.
Comfort Closure 1: the door lock pulse (or 2nd pulse for double pulses) will remain on for 20 sec-2.
onds.
Comfort Closure 2: 800mS following the end of the door lock pulse (or 2nd pulse for double pulses); 3.
the door lock output will turn on again for 20 seconds.
10. Horn Function
Full Alarm Only: the horn output will pulse only during full trigger events.1.
Siren Function 20/30/40/50ms: The horn output will emulate the siren output with selectable chirp 2.
output timing to compensate for OEM horn inefficiency.
Komentarze do niniejszej Instrukcji