1. One-time Bypass
Off: One-Time Bypass is not available1.
On: the One-Time Bypass feature will defeat Passive Arming once and, if Armed by remote control, 2.
will defeat Comfort Closure and Aux outputs linked to Arming
2. Override Pulse Count
1-5: sets the number of presses (1-5) on the Control Button required to override the alarm system•
3. Door Trigger error Chirp
On: if the door trigger is active when arming, the siren will emit a chirp and a message will be sent 1.
to the 2way remote control as an alert
Off: an active door trigger when arming will not create an alert output2.
4. Ign-controlled Dome light
On: the dome light output will activate when the ignition is turned off1.
Off: the dome light output will not activate when the ignition is turned off2.
5. OEM Alarm Disarm w/Aux/Trunk
On: the OEM Alarm Disarm wire will pulse as programmed when the Aux/Trunk output is activated1.
Off: the OEM Alarm Disarm wire will not pulse when the Aux/Trunk output is activated2.
6. OEM Alarm Disarm Output
With Unlock: the OEM Alarm Disarm wire will pulse as programmed at the same time as the unlock 1.
(Blue) wire
Before Unlock: the OEM Alarm Disarm wire will pulse as programmed before the unlock wire2.
7. OEM Alarm Disarm Pulses
1: the OEM Alarm Disarm wire will pulse once per operation1.
2: the OEM Alarm Disarm wire will pulse twice per operation2.
8. Aux/Trunk Output Type
Refer to Aux 1 Output Type descriptions1.
9. Aux/Trunk Linking
Refer to Aux 1 Linking descriptions1.
10. Aux 1 Output Type
Validity: when the Aux command is received the wire will turn on and remain on until the command 1.
ceases
Latch: when the Aux command is received the wire will turn on and remain on until the command is 2.
received again
Latch/reset/Ignition: when the Aux command is received the wire will turn on and remain on until the 3.
command is received again or the ignition is turned on/off
Timed: when the Aux command is received the wire will turn on for the programmed time duration 4.
(default 30sec)
Off: the output will not activate for a remote control command, use this option when the Aux com-5.
mand controls an external device such as a garage door module
OEM alarm arm: the output will not activate for a remote control command, it will pulse when the 6.
system arms to activate the OEM alarm system.
2nd unlock: the wire will operate as 2nd unlock and will not activate for remote control commands7.
Remote start report: the output will pulse once to activate an add-on remote start module and the 8.
Trunk Pin wire (H1/7) will be monitored for a ground input to confirm remote start activation.
11. Aux 1 Linking
No Linking: the Aux output will not activate for a remote control command1.
Link to Arm: the Aux output will activate for the Arm command2.
Link to Disarm: the Aux output will activate for the Disarm command3.
Link to Arm/Disarm: the Aux output will activate for the Arm & Disarm commands4.