Siren Duration: sets the Full Trigger output duration in 1 second intervals up to 180 seconds.1.
Sensor 1 level: directly sets the sensor level of the on-board shock sensor2.
Zone 4 Sensor Icon Type: sets the Zone 4 (Sensor 2) name to be displayed in the Text Field for Warn-3.
away and Full Trigger activations
Zone 7 Sensor Icon Type: sets the Zone 7 (Sensor 3) name to be displayed in the Text Field for Warn-4.
away and Full Trigger activations
Aux/Trunk Icon Type: sets the name to be displayed in the text field when the Aux/Trunk output is acti-5.
vated/de-activated
Aux 1 Timed Output: sets the output duration in 1 second intervals up to 90 seconds for Aux 16.
Aux 1 Icon Type: sets the Accessory name to be displayed in the text field when the Aux 1 output is ac-7.
tivated/de-activated
Aux 2 Timed Output: sets the Aux 2 “Timed” output in 1 second intervals up to 90 seconds8.
Aux 2 Icon Type: sets the Accessory name to be displayed in the text field when the Aux 2 output is ac-9.
tivated/de-activated
Aux 3 Timed Output: sets the Aux 3 “Timed” output in 1 second intervals up to 90 seconds10.
Aux 3 Icon Type: sets the Accessory name to be displayed in the text field when the Aux 3 output is ac-11.
tivated/de-activated
Aux 4 Timed Output: sets the Aux 4 “Timed” output in 1 second intervals up to 90 seconds12.
Feature Programming: locks and unlocks the user’s ability to enter the feature menus and manually 13.
change the main unit programming using the Control Center
Transmitter Programming: locks and unlocks the user’s ability to enter the remote control/Reset menu and 14.
manually change any functions using the Control Center